Rockchip cpu avs device tree bindings ------------------------------------- Under the same frequency, the operating voltage tends to decrease with increasing leakage. so it is necessary to adjust opp's voltage according to leakage for power. Required properties: - cluster-id: At runtime, the platform can find a cpu's cluster_id according to it's cpu_id and match cluster-id property. - min-volt: The minimum voltage in uV. Even though opp's voltage will be adjusted, it must be bigger than or equal to the minimum. - min-freq: The minimum frequency in KHz. If an opp's frequency is bigger than or equal to the minimum, its volatge will be adjusted. - leakage-adjust-volt: The property is an array of 3-tuples items, and each item consists of leakage and voltage like . min-leakage: minimum leakage in mA, ranges from 0 to 254. max-leakage: maximum leakage in mA, ranges from 0 to 254. volt: voltage offset in uV to apply to the opp table entries. - nvmem-cells: A phandle to the leakage data provided by efuse. - nvmem-cell-names: Should be "cpu_leakage". Example: cpu_avs: cpu-avs { cluster0-avs { cluster-id = <0>; min-volt = <800000>; /* uV */ min-freq = <408000>; /* KHz */ leakage-adjust-volt = < /* mA mA uV */ 0 254 0 >; nvmem-cells = <&cpul_leakage>; nvmem-cell-names = "cpu_leakage"; }; cluster1-avs { cluster-id = <1>; min-volt = <800000>; /* uV */ min-freq = <408000>; /* KHz */ leakage-adjust-volt = < /* mA mA uV */ 0 254 0 >; nvmem-cells = <&cpub_leakage>; nvmem-cell-names = "cpu_leakage"; }; };